翻訳と辞書
Words near each other
・ Diffuse idiopathic skeletal hyperostosis
・ Diffuse infantile fibromatosis
・ Diffuse infiltrative lymphocytosis syndrome
・ Diffuse Infrared Background Experiment
・ Diffuse interstellar bands
・ Diffuse intrinsic pontine glioma
・ Diffuse lamellar keratitis
・ Diffuse large B-cell lymphoma
・ Diffuse leprosy of Lucio and Latapí
・ Diffuse myelinoclastic sclerosis
・ Diffuse neonatal hemangiomatosis
・ Diffuse noxious inhibitory control
・ Diffuse optical imaging
・ Diffuse panbronchiolitis
・ Diffuse proliferative nephritis
Diffuse reflectance infrared fourier transform
・ Diffuse reflection
・ Diffuse series
・ Diffuse sky radiation
・ Diffuse unilateral subacute neuroretinitis
・ Diffused lighting camouflage
・ Diffuser
・ Diffuser (automotive)
・ Diffuser (band)
・ Diffuser (breathing set part)
・ Diffuser (heat)
・ Diffuser (optics)
・ Diffuser (sewage)
・ Diffuser (thermodynamics)
・ Diffusing capacity


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Diffuse reflectance infrared fourier transform : ウィキペディア英語版
Diffuse reflectance infrared fourier transform
Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS)〔C.-P. Sherman Hsu, Ph.D. "Handbook of Instrumental Techniques for Analytical Chemistry" Prentice-Hall, New Jersey, 1997, 262.〕 is an infrared spectroscopy technique used on powder samples with no preparation. The sample is added to a sample cup and the data is collected on the bulk sample. The infrared light on a sample is reflected and transmitted at different amounts depending on the bulk properties of the material. The diffuse reflection is produced by the sample's rough surfaces' reflection of the light in all directions and is collected by use of an ellipsoid or paraboloid mirror. Shape, compactness, refractive index, reflectivity and absorption of the particles are all characteristic of the material being analyzed. If the sample is too absorbent, then it can be diluted with a nonabsorbent material such as potassium bromide, potassium chloride, etc. The particle size should be smaller than the wavelength of the incident light, so this would infer that it should be less than 5 µm for mid-range infrared spectroscopy. The spectra are plotted in units of log inverse reflectance (log 1/R) versus wavenumber. Alternative plots of Kubelka-Munk units can be used, which relate reflectance to concentration using a scaling factor.
==References==


抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Diffuse reflectance infrared fourier transform」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.